Skip to main navigation Skip to main content Skip to page footer

Didactum 4-20mA Connector – Professional integration of analog sensors into IT and infrastructure monitoring

Didactum 4-20mA Connector

The Didactum 4-20mA Connector enables the simple and reliable integration of analog 4-20mA sensors into Didactum IT monitoring systems. This allows central collection, supervision, and documentation of diverse measurements such as temperature, humidity, pressure, fill levels, or industrial process values. For server room monitoring, data center security, or critical infrastructures, this connector provides maximum flexibility and safety.

Easy Installation & Configuration

Commissioning the 4-20mA Connector is straightforward:

  • Connection via RJ-11 cable to an analog port (A1–A8) of the Didactum system
  • AutoSense: automatic detection in the web interface
  • Individual configuration of measurement types, labels, and thresholds
  • Real-time alerts via e-mail, SMS, or SNMP trap when thresholds are exceeded

Integration into Critical Infrastructure

The 4-20mA Connector opens up a wide range of use cases beyond standard environmental sensors. Examples include:

  • UPS monitoring: supervision of emergency power supply
  • Fill level monitoring: tanks, water reservoirs, or industrial fluid systems
  • Pressure control: differential pressure sensors in HVAC or clean rooms
  • Leakage warning systems: integration of specialized moisture sensors
  • Process monitoring: documentation of industrial & production parameters

Scalability & Remote Monitoring

By connecting multiple analog 4-20mA sensors and using Didactum port expansion modules, extensive infrastructures can be monitored. All values are:

  • displayed in real time via the web interface
  • integrated via SNMP v1/v2c/v3 into monitoring tools such as Nagios, PRTG, Zabbix, or OpenNMS
  • archived for long-term analysis (with storage options up to 500 GB)
  • shown in centralized dashboards across sites

Typical Use Cases

  • Server room monitoring: integration of temperature and humidity sensors
  • Data center security: alarms for anomalies in climate data or power supply
  • UPS monitoring: supervision of battery voltage and emergency supply systems
  • HVAC & building systems: differential pressure or air quality control
  • Industrial processes: integration of fill level or process sensors
  • Early fire detection: connection of analog smoke or temperature detectors

Benefits for Enterprises

  • Flexible integration of 4-20mA sensors into Didactum systems
  • Universal applications in IT monitoring, energy management, and industrial processes
  • Reliable alerting via e-mail, SMS, or SNMP
  • Scalable design for monitoring large infrastructures
  • Easy operation via the Didactum web interface
  • Audit- & compliance-ready with continuous event logging

Practical Examples

  • Data center: integration of differential pressure sensors in cold aisle containment
  • Server room: connection of analog smoke and temperature detectors for early fire detection
  • Energy plant: monitoring of cooling water levels and pressure sensors
  • Industry: comprehensive process monitoring with multiple 4-20mA sensors in series

FAQ – Frequently Asked Questions

Which sensors can be connected?
All analog sensors with a 4-20mA current interface (e.g., temperature, pressure, fill level, humidity).

How is the connector installed?
Via RJ-11 connection to Didactum monitoring systems’ analog ports (A1–A8).

Are alerts supported?
Yes, via e-mail, SMS, or SNMP trap if thresholds are exceeded.

Can multiple sensors be integrated?
Yes, via sensor port extensions and in combination with Didactum modules.

Is the connector suitable for industrial applications?
Yes, it ensures flexible integration in HVAC, energy, process, and security monitoring.

The Didactum 4-20mA Connector enables the direct integration of analog 4-20mA sensors into professional monitoring systems. Whether for temperature, humidity, pressure, or fill levels – all parameters are captured, monitored, and archived in real time. With SNMP integration, AutoSense, instant alerting, and scalability, it is a vital tool for ensuring efficiency and safety in server rooms, data centers, industrial processes, and critical infrastructures.

Didactum 4-20mA Connector

Didactum 4-20mA Connector
The Didactum 4-20mA Connector is a central element for professional server room monitoring and critical infrastructure supervision. This connector allows direct integration of analog sensors that output a 4-20mA current signal into Didactum’s network-based monitoring systems.

This enables you to centrally record and evaluate various measured values such as temperature, humidity, pressure, fill levels, and industrial process parameters. The flexible integration is a decisive advantage, especially in sensitive areas like server rooms, data centers, or critical company environments.

This website uses cookies

This website uses cookies to improve user experience. By using our website you consent to all cookies in accordance with our Cookie Policy.

Essential cookies enable basic functions and are necessary for the website to function properly.
Statistics cookies collect information anonymously. This information helps us to understand how our visitors use our website.
Marketing cookies are used by third parties or publishers to display personalized advertisements. They do this by tracking visitors across websites.